Looking after your boat batteries while you're away

Batteries fail quietly. A boat left for a few months with a small parasitic drain, a faulty charger or the wrong storage setting can come back to batteries that will not hold a charge. Replacing a house bank is expensive, and avoiding it mostly takes a few simple habits.

Key points

  • Never leave lead-acid or AGM batteries discharged: they sulphate and lose capacity permanently.
  • Lithium (LiFePO4) batteries usually prefer to be stored part-charged, around 50–60%, not held at 100% for months. Check your manufacturer's advice.
  • Make sure the charger is set to the right battery type and has a storage or float mode.
  • Find and switch off parasitic loads, or isolate the batteries if there is no shore power.
  • A monthly resting-voltage check catches most problems early.

Know which batteries you have

Look at the battery labels and the charger settings. Most boats have one of three types: flooded lead-acid, sealed AGM or gel, or lithium iron phosphate (LiFePO4). They need different charging voltages and different storage, and a charger set for the wrong type will slowly damage the bank.

Lead-acid and AGM

  1. Charge fully before you leave. Lead-acid batteries sulphate when they sit partly discharged, and that capacity does not come back.
  2. Keep them topped up. Either stay on shore power with a smart charger in float mode, or isolate them and recharge every month or two.
  3. Check electrolyte in flooded batteries before the lay-up and top up with distilled water only.
  4. Clean the terminals and protect them with terminal grease.

Lithium (LiFePO4)

Lithium batteries are lighter and last longer, but they have their own rules. Most manufacturers recommend storing them at a partial charge, often around 50–60%, and not holding them at 100% on float for months. Many also advise against charging below freezing. The battery management system (BMS) protects the cells, but it draws a small current too, so a lithium bank left isolated for a very long time should still be checked. Always follow the manufacturer's storage advice for your specific battery.

Hunt down parasitic loads

Bilge pump float switches, alarms, radio memory, chartplotter standby, monitoring systems and some inverters all draw current with everything apparently switched off. Some of these, like the automatic bilge pump, should stay powered. The rest should be switched off at the panel. If there is no shore power, a small solar panel with a proper controller can cover the essential loads.

The monthly voltage check

For a 12 V lead-acid or AGM battery that has rested for a few hours without charging or load, the voltage tells you roughly how charged it is:

Resting voltageApproximate chargeWhat to do
12.7 V or moreFullNothing
about 12.4 VAbout 75%Charge soon
about 12.2 VAbout 50%Charge now
below 12.0 VClose to flatCharge now and find the cause

Lithium batteries hold an almost flat voltage across most of their range, so voltage is a poor guide. Use the battery monitor or BMS app instead.

Check the charger itself

A charger that has failed, tripped or been unplugged by a neighbour is a common cause of flat batteries in a marina. When the boat is checked, confirm that shore power is connected, the charger shows the right stage and the cable is not damaged or lying in water.

Tip: take a photo of the charger and battery monitor screens at every visit. Over a winter, the photos show whether the batteries are holding up or slowly fading.